Policy for Chemical Dispensing Systems

 

Mass Gov logo

Click here for more information from the Mass.gov site


Regarding an Alternative to the Existing Chemical Cleaning Dispenser Policy

Enacted September 1, 2010  
(Jurisdiction regarding this policy  is governed by 310 CMR).

NOTICE: Chemical Cleaning Dispensers incorporating the Alternative Hose Connection, approved by the Board shall not require a permit and may be installed by an unlicensed person.

HOSE CONNECTION

The Board of State Examiners of Plumbers and Gas Fitters voted to allow a water hose connection as an alternative to the hard plumbing requirement for Chemical Dispensing Systems installed in the Commonwealth provided the dispensers meet the following requirements.
1.        All dispensers shall have an Air Gap or, an alternative Certification of Listing under the ASSE 1055B Standard.
2.        Dispensers shall include a dual check valve with an atmospheric vent device installed at the water inlet as a secondary backflow protection.
3.        A stainless steel or nylon braided hose must be used.
4.        A pressure bleeder device shall be provided which will visually free flow water through the atmosphere from the faucet connection to a sink or drain. The purpose of the bleeder device is to indicate that the water is running and should be shut off to prevent hot water migration. The bleeder device shall connect to the water source utilizing a quick disconnect coupling.
5.        All external components will be permanently installed on the dispenser by the manufacturer and be ready for installation and use. External components include the dual check valve with atmospheric vent, stainless steel braided hose and the pressure bleeder device.